Critical backup failure during data transfer (Agent Export error occurred mid transfer)

Run the below commands:(As an administrator:

  • vssadmin Add ShadowStorage /For=C: /On=C: /MaxSize=UNBOUNDED
  • vssadmin create shadow /for=C:

Then Delete the C: drive Data set from the portal

go to protect Tab > Configure Agent Setting  >  volume Level Backup Control  > delete the C data set.

Start Backup

or:

  1. Expand Shadow Copy Storage:
    • Open Command Prompt as Administrator and run:

      vssadmin resize shadowstorage /for=C: /on=C: /maxsize=UNBOUNDED
      vssadmin resize shadowstorage /for=D: /on=D: /maxsize=UNBOUNDED
    • This ensures VSS has enough space.
  2. Clear Existing VSS Snapshots:
    • Run:

      vssadmin delete shadows /all

      Then:

      Delete the C: drive Data set from the portal

      go to protect Tab > Configure Agent Setting  >  volume Level Backup Control  > delete the C data set.

      Start Backup

 

  • 0 Пользователи нашли это полезным
Помог ли вам данный ответ?

Связанные статьи

Backup Verification Failure (boot error)

Connect to the server and run the following commands: sfc /scannow Dism /Online /Cleanup-Image...

Robocopy command

 robocopy [source] [destination] /mir /Z /W:5 /fft /R:3 /secfix /copyall exp: robocopy F: D:...

Streaming and Processing On cloud

To start, run the following commands on the machine itself. Once each of these commands is...

Replacing RAM on Alto5

Power off and unplug the device. Remove the two screws covered by the two rubber feet on...

Input Output Error On C(I/O Error) on C Drive